Animation movements come in two basic flavors: 1) Analog, and 2) Digital. Although
we are used to thinking of everything ‘digital’ being superior to anything analog (like
digital CDs vs. analog LP records), this is the one case where it just ain’t so
1
. Analog
movements are used in almost all high-end animated figures. They give you a fluid,
lifelike motion that digitals just can’t do.
GILDERFLUKE & CO. • 205 SOUTH FLOWER ST. • BURBANK, CALIF. 91502-2102 • 818/840-9484 • FAX818/840-9485
1 of 12
1
Digital electronics are used to create most analog Animation Control Systems.
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - FEEDBACK CONTROLLER

- OPERATINGINSTRUCTIONS-- for -- EFB-QUAD ELECTRONIC FEEDBACK CONTROLLER -- PID-QUAD ELECTRONIC FEEDBACK CONTROLLER -- printed February 27, 2006 -Anim

Seite 2

EFB-Quad Adjustment:Adjusting an EFB movement is part skill and part art. Unfortunately it must be done to taste, so thereare no set rules about mak

Seite 3

Quad D/A and EFB (“George Board”):This board combines the functions of a Quad D/A converter and a Quad EFB. The adjustments are acombination of tho

Seite 4

#5 15 green J6 out channel 0 bit 4 #6 16 blue J6 out channel 0 bit 3 #7 17 violet J6 out channel 0 bit 2 #8 18 gray J6 out channel 0 bit 1#9 19 white

Seite 5 - Installation:

A Digital control is either off or on, just like a light switch. A typical digital animationmovement is at either one end of its travel or the other,

Seite 6

any given instant. When using a potentiometer, this can add from $25 (for a rotary pot) to$100 or more (for a linear pot or LVDT).Electronic FeedBack

Seite 7 - EFB-Quad and PID-Quad Inputs:

The PID-Quad also features what are called ‘Compliance’ inputs. This adds a second‘force’ feedback to an analog movement. This is usually a strain g

Seite 8

If any channels are left unused on the EFB-Quad or PID-Quad controller, you will needto short together the transducer inputs on the unused channels to

Seite 9

calculating the approximate displacement of the cylinder and comparing it to the cubic feet per minute(CFM) capacity of the valve.A number of differen

Seite 10 - PID-Quad Adjustment:

EFB-Quad and PID-Quad Inputs:The inputs to the EFB-Quad and PID-Quad are a standard 1/4 J6/A cables. This typically comes from aBS-ANA or other analo

Seite 11

EFB-Quad and PID-Quad Adjustments:There are two adjustments available on each of the four channels on an EFB-Quad, and eightadjustments per channel

Seite 12

completely disconnected. Most valves have some sort of setscrews or other mechanicaladjustments which will allow you to center the valve until the